10-22-2021
#1
WorkCenter 6515, error 062-380
Hello Companions.
First to say that I do not handle this brand (I am a ricoh technician/distributor), it is a request from a customer, who has a Xerox WorkCenter 6515, and asks my technical department if we can solve this problem.
The device throws this fault code «062-380» so it does not allow you to operate, someone can lend a hand. Thank you.
Apologies for my English, it’s not my mother tongue and I’m helping the translator.
ALL WILL BE WELL
-
10-22-2021
#2
Re: WorkCenter 6515, error 062-380
Insufficient lamp brightness was detected when performing AGC.
-
10-25-2021
#3
Re: WorkCenter 6515, error 062-380
Originally Posted by adriansto
Se detect� un brillo insuficiente de la l�mpara al realizar AGC.
I understand that this failure may be due to the explorer’s lamp being dirty, or it being melted/broken.
True? In the case of dirt, it should be possible to clean both the lamp and the mirrors of the explorer.
You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.
Last edited by UNICORNico; 10-25-2021 at 04:09 PM.
Apologies for my English, it’s not my mother tongue and I’m helping the translator.
ALL WILL BE WELL
-
10-25-2021
#4
Re: WorkCenter 6515, error 062-380
[QUOTE=UNICORNico;1945975]
Originally Posted by adriansto
You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.
It is about scanner lamp. Under the scanner glass it is white band ( label ) Check that label is clean, check if the scanner mirrors are clean. All of these works on AGC = Automatic Gain Control
-
10-25-2021
#5
Junior Member
- Rep Power
- 0
Re: WorkCenter 6515, error 062-380
You have to replace the IIT assy , ie the scanner assy below is description of the fault ,
062-311, 313, 321, 360, 371, 380, 386, 389, 393, 396-398 IIT
Fail RAP
062-311 Error detected in IISS software.
062-313 Unexecutable Scan command error.
062-321 Unexecutable Scan command error.
062-360 Carriage home position error is detected.
062-371 IIT failure Lamp error is detected.
062-380 Insufficient lamp brightness was detected when performing AGC.
062-386 During AOC (darkness adjustment), detected CCD output error.
062-389 Overrunning of CRG was detected.
062-393 CISASIC communication error is detected.
062-396 Connection problem of CIS flat cable was detected.
062-397 Connection problem of ESS Video cable was detected.
062-398 Connection problem of ESS I/O cable was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to [GP 4]. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
1. Power the machine down then back up, [GP 4], the error persists,
2. Clean the scanner platen and the white stripe, [GP 34], the error persists,
3. Install a new IIT Assembly, [REP 50.1.2], the error persists,
4. Install a new DADF Assembly, [REP 50.1.1],
Модератор: vetal
-
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4
- 5
- 5709
3100
Пн ноя 18, 2019 8:24 pm
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
-
-
Xerox WC 3119: «Замятие 1»
kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4
- 22
- 39533
kokubenko
Ср ноя 23, 2011 4:47 pm
-
Xerox WC 3119: «Замятие 1»
-
-
«Неисправность» финишера Xerox 7556
v1684 в форуме Принтеры, МФУ, копиры формата A3
- 21
- 13346
v1684
Ср сен 19, 2018 4:44 pm
-
«Неисправность» финишера Xerox 7556
-
-
Xerox WC3220 — Ложное замятие бумаги, Замятие 0
Romeo в форуме Принтеры, МФУ, факсы, копиры формата A4
- 25
- 11302
Romeo
Пн окт 12, 2020 7:13 pm
-
Xerox WC3220 — Ложное замятие бумаги, Замятие 0
-
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
Володья в форуме Принтеры, МФУ, факсы, копиры формата A4
- 8
- 12985
Володья
Сб апр 30, 2011 8:05 am
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
Вернуться в Принтеры, МФУ, факсы, копиры формата A4
Кто сейчас на форуме
Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 66
NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the
Change Settings button) to check the value (diagnosis result).
Table 1 LED
Current value
Component Name
00
Not applicable (No errors)
01
LED Lamp PWB
02
CCD Lens Assembly
03
CCD Flexible Flat Cable
10
LED Lamp Flexible Flat Cable
12
IIT-ESS Video Cable
14
IIT-ESS I/O Cable
17
LVPS-IIT/Fax Power Cable (DC Harness)
4.
After replacing the appropriate parts, again change the value for NVM location [715-030]
to «1» and then execute «NVM Write».
5.
Check that the current value column becomes «000».
6.
If the problem persists after performing the above procedure, continue and check the fol-
lowing:
•
LED Lamp broken:
Component Control
•
Check the Flat Cable between the LED Lamp PWB
J723
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
Check the Flat Cable between the CCD Lens Assembly
J710
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
The coaxial cable between the IIT PWB
open circuit, short circuit, and poor contact
Initial Issue
WorkCentre 5335 Family Service Documentation
PL No.
—
PL 1.4
PL 1.2
PL 1.2
PL 1.4
PL 18.4
PL 18.4
PL 18.4
[062-002]
(PL
1.2)
P/J7001
and the IIT PWB
P/J700
and the IIT PWB
P/J7191
and the ESS PWB
P/J336
BUS Updated 12/2011
BSD-ON:
BSD 6.1 — Document Illumination
BSD-ON:
BSD 6.6 — Image Input
Insufficient lamp brightness was detected when performing AGC.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Initial Actions
Check the light path for any obstacle, and the lamp, the lens, the mirror and the White Correct-
ing Plate for deterioration or contamination.
Procedure
1.
Turn the power ON and enter the Diag mode. Change the value for NVM location [715-
030] to «1» and then execute «NVM Write».
2.
A 3 or 4-digit number is displayed in the current value column.
3.
Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace
the appropriate parts.
Sample Display
•
110 (3-digit display):
P/
LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor
contact.
P/
(The first digit «1» in «110» is the upper digit, which indicates the LED Lamp PWB («0»
in «01» is not displayed). The lower 2 digits «10» indicates the LED Lamp Flexible Flat
Cable.)
for
•
1000 (4-digit display):
The LED Lamp Flexible Flat Cable is damaged or has poor contact.
(The first 2 digits «10» in «1000» are the upper digits, which indicates the LED Lamp
Flexible Flat Cable. The lower 2 digits «00» indicates that nothing is applicable (no
failures).)
07/2011
2-779
Status Indicator RAPs
062-371, 062-380
Go to printers
r/printers
Inkjets, lasers, thermal, commercial and industrial printers.
We make printers suck less by promoting printer maintenance, troubleshooting and providing accurate recommendations.
Members
Online
•
Xerox Workcentre 6515 error 062-380 & 062-386
Hey I have this printer and got both of these error codes. From my research it appears to be something with the scanner, possibly a lose connector or bad sensor.
From reading other posts it sounds like I may be able to order a new scanner module.
Also if anyone has a link to a service manual that tells me how to replace it, maybe I could use that to check for a lose connection.
Модератор: vetal
-
- Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4
- 5
- 5303
3100
Пн ноя 18, 2019 8:24 pm
- Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
-
- Xerox WC 3119: «Замятие 1»
kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4
- 22
- 38601
kokubenko
Ср ноя 23, 2011 4:47 pm
- Xerox WC 3119: «Замятие 1»
-
- «Неисправность» финишера Xerox 7556
v1684 в форуме Принтеры, МФУ, копиры формата A3
- 21
- 12643
v1684
Ср сен 19, 2018 4:44 pm
- «Неисправность» финишера Xerox 7556
-
- Xerox WC3220 — Ложное замятие бумаги, Замятие 0
Romeo в форуме Принтеры, МФУ, факсы, копиры формата A4
- 25
- 10131
Romeo
Пн окт 12, 2020 7:13 pm
- Xerox WC3220 — Ложное замятие бумаги, Замятие 0
-
- прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
Володья в форуме Принтеры, МФУ, факсы, копиры формата A4
- 8
- 12680
Володья
Сб апр 30, 2011 8:05 am
- прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
Вернуться в Принтеры, МФУ, факсы, копиры формата A4
Кто сейчас на форуме
Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 123
NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the
Change Settings button) to check the value (diagnosis result).
Table 1 LED
Current value
Component Name
00
Not applicable (No errors)
01
LED Lamp PWB
02
CCD Lens Assembly
03
CCD Flexible Flat Cable
10
LED Lamp Flexible Flat Cable
12
IIT-ESS Video Cable
14
IIT-ESS I/O Cable
17
LVPS-IIT/Fax Power Cable (DC Harness)
4.
After replacing the appropriate parts, again change the value for NVM location [715-030]
to «1» and then execute «NVM Write».
5.
Check that the current value column becomes «000».
6.
If the problem persists after performing the above procedure, continue and check the fol-
lowing:
•
LED Lamp broken:
Component Control
•
Check the Flat Cable between the LED Lamp PWB
J723
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
Check the Flat Cable between the CCD Lens Assembly
J710
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
The coaxial cable between the IIT PWB
open circuit, short circuit, and poor contact
Initial Issue
WorkCentre 5335 Family Service Documentation
PL No.
—
PL 1.4
PL 1.2
PL 1.2
PL 1.4
PL 18.4
PL 18.4
PL 18.4
[062-002]
(PL
1.2)
P/J7001
and the IIT PWB
P/J700
and the IIT PWB
P/J7191
and the ESS PWB
P/J336
BUS Updated 12/2011
BSD-ON:
BSD 6.1 — Document Illumination
BSD-ON:
BSD 6.6 — Image Input
Insufficient lamp brightness was detected when performing AGC.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Initial Actions
Check the light path for any obstacle, and the lamp, the lens, the mirror and the White Correct-
ing Plate for deterioration or contamination.
Procedure
1.
Turn the power ON and enter the Diag mode. Change the value for NVM location [715-
030] to «1» and then execute «NVM Write».
2.
A 3 or 4-digit number is displayed in the current value column.
3.
Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace
the appropriate parts.
Sample Display
•
110 (3-digit display):
P/
LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor
contact.
P/
(The first digit «1» in «110» is the upper digit, which indicates the LED Lamp PWB («0»
in «01» is not displayed). The lower 2 digits «10» indicates the LED Lamp Flexible Flat
Cable.)
for
•
1000 (4-digit display):
The LED Lamp Flexible Flat Cable is damaged or has poor contact.
(The first 2 digits «10» in «1000» are the upper digits, which indicates the LED Lamp
Flexible Flat Cable. The lower 2 digits «00» indicates that nothing is applicable (no
failures).)
07/2011
2-779
Status Indicator RAPs
062-371, 062-380
Thanks: 0
Likes: 0
Dislikes: 0
-
04-08-2013
#1
I really need some help on this one. I have a Xerox 4110 with a fault code 062-380. I have cleaned the optics and white strip. I have re-initialized the system more than once. If I turn the unit off, and unplug it, it will come ready, but if I restart it, the code comes back. The manual says to change the ccd and lens. I want to know if anyone has had this problem and if there is something I can do before ordering the expensive parts the manual says I need.
-
04-09-2013
#2
Re: 4110 Code 062-380
You might have a bad CCD. Check the optics cooling fans also.
-
04-09-2013
#3
Re: 4110 Code 062-380
Reseat CCD and IPS cabling. Retry. If problem returns, replace the CCD.
I have had this once on a 4112. I replaced the CCD and that took care of the problem.
-
04-10-2013
#4
Field Supervisor
500+ Posts
- Rep Power
- 40
Re: 4110 Code 062-380
it is the ccd lens assembly also the copy bottom is not activated, just replace the lens assembly it should resolve the fault code.
Get your facts first, and then you can distort them as much as you please.
-
04-15-2013
#5
Re: 4110 Code 062-380
Thanks guys, the lens/ccd kit worked.
-
05-15-2016
#6
Senior Tech
100+ Posts
- Rep Power
- 27
Re: 4110 Code 062-380
Hi,
Could anyone share with me the part # for this CCD assy?
Thank You
-
05-21-2016
#7
Junior Member
- Rep Power
- 0
Re: 4110 Code 062-380
Originally Posted by vishop
Hi,
Could anyone share with me the part # for this CCD assy?
Thank You
604k21506 p/n
Tags for this Thread
Bookmarks
Bookmarks

Posting Permissions
- You may not post new threads
- You may not post replies
- You may not post attachments
- You may not edit your posts
- BB code is On
- Smilies are On
- [IMG] code is On
- [VIDEO] code is On
- HTML code is Off
Forum Rules