1015 ошибка microsoft windows wininit

  • Remove From My Forums
  • Question

  • System:Window 2012

    Error Message:

    A critical system process, C:Windowssystem32lsass.exe, failed with status code c00000fd.  The machine must now be restarted.

    I started myself window service, The log have other log:

    System.AccessViolationException: Attempted to read or write protected memory. This is often an indication that other memory is corrupt.

    And wait 3-4min, The server will restart.

    • Edited by

      Wednesday, April 27, 2016 9:02 AM

Answers

  • Hi,

    Thanks for your reply.

    The «-1073741571» error may occur if the registry data type for the SearchList entry is set to a Dword value type (REG_DWORD) instead of to a String value type (REG_SZ) in the registry.

    To resolve the problem that is related to the «-1073741571» error, follow these steps:

    1. Start your computer in Safe Mode.

    2. Click Start, click Run, type regedit in the
    Open box, and then click OK.

    3. Locate and expand the following registry subkey:

    HKEY_LOCAL_MACHINESYSTEMCurrentControlSetServicesTcpipParameters

    4. Change the data type from REG_DWORD to REG_SZ. To do this, follow these steps:

    1. In the right pane, right-click SearchList, and then click
      Delete
      .
    2. Click Yes to confirm that you want to delete this entry.
    3. On the Edit menu, point to New, and then click
      String Value.     
    4. Type SearchList, and then click OK.

    5. Quit Registry Editor.

    6. Restart your computer.

    Note: Taking a backup before modifying the registry.

    Best Regards,

    Alvin Wang


    Please remember to mark the replies as answers if they help and un-mark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact tnmff@microsoft.com.

    • Edited by
      Alvwan
      Tuesday, May 3, 2016 9:34 AM
    • Proposed as answer by
      Alvwan
      Monday, May 9, 2016 8:00 AM
    • Marked as answer by
      Alvwan
      Thursday, May 12, 2016 8:33 AM

  • error 0xc0000135 on a windows server 2003 R2.

    Whenever I want to run any app, I get error 0xc0000135 on a windows server 2003 R2.

    Anyone has a solution, because it can be run almost anything same not my antivirus.

    Hello

    Post your question in the TechNet Server Forums, as your question kindly is beyond the scope of these Forums.

    http://social.technet.Microsoft.com/forums/WindowsServer/en-us/home?category=WindowsServer

    See you soon.

  • How to solve (Exception from HRESULT: 0x80070005 (E_ACCESSDENIED)) error when installing on Windows Server 2008 R2 COM component

    How to solve (Exception from HRESULT: 0x80070005 (E_ACCESSDENIED)) error when installing on Windows Server 2008 R2 COM component

    Please repost your request in one of the appropriate Forums for Windows Server.  Thank you!

  • VB6 DLL is not log messages in the Windows Server 2003 event log when it is called from an ASP page

    Hi all

    I have an ASP web application, I will create a «VBModule1» (VB6 Dll) instance of an ASP page and inside this method of «VBModule1» I create an instance of another VB6 Dll ‘VBLogger’, who calls App.LogEvent () to write messages to the event log.

    I tested the Web application on the develepoment (XP) machine and everything worked fine but when the user runs the Web application on the Production Server (windows server 2003) events are not saved.

    Friend missing the security settings of my ASP web app that needs to be configured on Windows Server 2003 for VB6 DLLs logging events?

    Please think as soon as POSSIBLE.

    IIS on Windows server 20003 version: 6.0

    Thank you.

    Hello

    The question you have posted is related to Windows Server 2003 would be better suited to the Windows Server community.

    Please visit the link below to find a community that will support what ask you:

    http://social.technet.Microsoft.com/forums/en-us/category/WindowsServer

  • 1E error blue screen on windows server 2008 r2

    Hi friends,

    Please help, I do face with blue screen error 1e, although helping to solve this problem,

    Signature of the problem:
    Problem event name: BlueScreen
    OS version: 6.1.7601.2.1.0.274.10
    Locale ID: 1033

    More information about the problem:
    BCCode: 1e
    BCP1: 0000000000000000
    BCP2: 0000000000000000
    BCP3: 0000000000000000
    BCP4: 0000000000000000
    OS version: 6_1_7601
    Service Pack: 1_0
    Product: 274_3

    Files helping to describe the problem:
    C:WindowsMinidump112914-22651-01.dmp
    C:UsersAdministratorAppDataLocalTempWER-73289-0.SysData.XML

    Read our privacy statement online:
    http://go.Microsoft.com/fwlink/?LinkId=104288&clcid=0x0409

    If the online privacy statement is not available, please read our offline privacy statement:
    C:Windowssystem32en-USerofflps.txt

    [Moved from the community centre of Participation]

    You will find the Windows Server support in these forums: http://social.technet.microsoft.com/Forums/windowsserver/en-US/home?category=windowsserver

  • Error during installation of Windows Server 2003

    I installed VMWare Player, however, when I went to install Windows Server 2003 (easy installation) on my windows 7 Home Edition (64-bit) as owner / administrator.

    The VMWare authorization Services do not seem to be started, but when I try to start them via the services.msc, I get the following error:

    «Windows failed to start the service on Local computer VMWare authorization Service.

    «Error 1067: the process terminated unexpectedly.»

    I studied this error and saw a few notes on adding __vmware_user__ my users the.  But with what privileges?

    I also saw a few notes on execution of «regsrv32 vmauxx.exe» which does not work on my computer.

    Any ideas on how to proceed?

    Thank you.

    Lee

    Welcome to the community,

    Installing on Windows 7 is sometimes delicate. Take a look at http://faq.sanbarrow.com/index.php?solution_id=1113 to verify that your installation is ok or how to fix it in case it is not.

    In addition to the installation of VMware Player, I suggest that you install the guest without using «Easy Install».

    André

  • Facing error code standard activate windows server 2008 r2 0x8007007b

    When I turn it on with the product key indicating this error.

    Kindly help me solve this problem

    * This windows server is for commercial use

    Hello

    Post your question in the TechNet Server Forums, as your question kindly is beyond the scope of these Forums.

    http://social.technet.Microsoft.com/forums/WindowsServer/en-us/home?category=WindowsServer

    See you soon.

  • Performance diagnosis is not available in the Windows Server 2008 Event Viewer

    In Event Viewer, I can see the Microsoft-Windows-Diagnostics-Performance/operational under Windows 7 but I couldn’t get under another computer running Windows 2008. Is it possible to allow that?

    Hello

    Your Windows is better suited for the Windows Server Forums on TechNet. Please post your question in the Windows Server Forums.

    http://social.technet.Microsoft.com/forums/en-us/category/WindowsServer/

  • VMware vCenter Converter Standalone 5.5.0 build-1362012 — unknown internal error trying to P2V Windows Server 2003 SP2

    I have a box of Windows Server 2003 SP2 Standard that fails to convert using vCenter Converter Standalone 5.5.0 build-1362012. After you submit the task in the wizard’s GUI, I get «a general error has occurred: unknown internal error». A virtual machine is created and deleted and then a few moments later.

    Create the virtual machine

    192.168.1.201

    Completed

    Search entity by UUID

    Completed

    Search entity by UUID

    Completed

    Remote disk open read-write

    Completed

    Search entity by UUID

    Completed

    Remote disk open read-write

    Completed

    Search entity by UUID

    Completed

    Delete the entity

    SRV-cspnsn. CSPNSN.local

    Completed

    The destination is VMware ESXI version 5.5.0 build-1623387 managed by vSphere Client version 5.5.50 build-1618071. The destination data store is a 5.60 VMFS volume with block size of 4 MB, on a local SATA HDD with 923, 50GB.

    Both machines are in the same network and have no any King or firewall or ACL in switches.

    In the log file, the only error is «error»Ufa.HTTPService»] Impossible to read the application; «flow: io_obj p:0x03403f24, h:-1, < tube».pipevmware-converter-server-soap»>, < pipe».pipevmware-converter-server-soap»> >, error: class Vmacore::TimeoutException (Operation timed out).

    Any help would be appreciated.

    Thanks in advance.

    Hi all

    Once the converter VMware-converter-en — 5.5.1 — 1682692 does not work, with a touch of friend uninstall the 5.5 version of Converter Standalone Client, look for the VMware converter version — 4.0.0 — 146302 and install this version to the other machine. No not that I had to be Converter, but the windows 7 Pro 64-bit.

    After this race, the Standalone Client 4.4 Converter and everything work fine.

    Now I have the P2V converted and good machine, as was the real operation!

    I thank all of you.

    Best regards

    ADAJio

  • Adobe Reader DC contains errors and crashes with Windows Server R2 2012

    We have recently installed Adobe Reader DC Adobe version on our servers Windows Server R2 2012 and have problems since its launch. Few of the questions that we have seen are as follows:

    1. This version is a little awkward and crashes.
    2. A lot of pop up boxes that appears whenever I open a document.
    3. Whenever I open a document it is a box pop up welcome
    4. It is a little slow to respond between clicks
    5. If I click on options like file. The application hangs and then crashes. (see crash message attachment)

    Any help to solve this problem would be useful.

    Thank you

    Adobe error.PNG

    Questions for users confronted with this question:

    1. do you have the preview pane enabled in file Explorer? If so, you can temporarily disable it to see if the problem goes away? On Windows 8, in Explorer, go to the view tab, and if you press the button «Preview Pane», UN-press it. On Windows 7, upwards to the right (to the left of the help icon) there is a button «show preview pane.» UN-press it.

    2. ensure that the following directories exist on your machine. If this isn’t the case, please create them:

    C:UsersUSERNAMEAppDataLocalAdobeAcrobatDCToolsSearchCacheAcro

    C:UsersUSERNAMEAppDataLocalAdobeAcrobatDCToolsSearchCacheRdr

    Replace USERNAME with your username.

    Is — do this 1 or 2 to solve this problem?

  • InDesign error code: 5 — on Windows Server or Qnap

    We continue to receive mean error code: 5 problems of corruption with our CC InDesign files on our corporate network. It doesn’t seem like there is a work beyond obvious autour back manually before opening a file.

    The behavioiur arrives on a variety of machines, always when you save the file (although corruption is not apparent, until you try to open the file again with the same or another machine).

    Longer with the OS X Mavericks machines on Windows file sharing, but also arises on the rapid sharing of Qnap, (SSD and a dual Gbit ethernet, versus 7200 RPM drives and a single Gbit ethernet link).

    All Gbit links with CAT6 network cabling. It’s an Active Directory environment.

    At this point, it is either Active Directory that throws the questions or it is from InDesign. Any other type of file were corrupted never well!

    Don’t think it’s OS X — although I have observed only corruption happening once (and I’m not 100% sure of the observation) with one of our machines Windows 8.

    Everyone suffers from this kind of problem? It is quite ordinary for us — occurs at least three or four times a week between 10 users…

    So we fixed that in our environment. I suspect it’s a combination of things.

    We have to switch and teaming network adapters on the server. That does not help him alone, although reduced the presence a little.

    So, we have improved the macs in Yosemite. Doesn’t really have much of a difference, but support for smb3 probably helped together with the next bit.

    We got a new, server of 2012 r2 for windows, with a very fast ssd raid array. No more code error 5.

    All this happened within a few months, so it is difficult to say if the impact fell with the first two changes. And I could not check if the new server was solely responsible, because we have not kept any Mac on the mavericks, and kept the old switch in the room. It seemed in any case mostly occur when we had very heavy traffic on the server (we are a Publisher, so generally it would be on our press days — is not ideal!).

    In any case, it is quite an expensive solution, but it has its good sides — everything is much more fluid, and windows 2012 is a breeze (relatively) to implement and administer.

  • Occasional errors of NTFS on Windows Server VM

    I have a Windows 2003 server that I sometimes (every 2 weeks or more) get NTFS errors during backup (Backup Exec 12.5).  It’s always the same drive (dynamic spanning two volumes).  The VM data store is on a NetApp iSCSI SAN.  If I run chkdsk, mistakes become clear.  That’s happened last night again.  I have a whole directory that is inaccessible today.  Hopefully chkdsk will fix it again.

    60 GB is a small disk, dynamic disks is the only way for volumes over 2 TB.

    You can extend your customer VI vmdk and then resize the NTFS with Dell ExtPart partition, gparted or any tool of partitioning that you like.

    MCSA, MCTS, VCP, VMware vExpert 2009

    http://blog.vadmin.ru

  • Error: lsass.exe. system error.

    Original title: «Lsass.exe» is there no solution?

    I’m runnng Windows XP, I made the recovery of the PC/3 times now. After recovery, I have to go through the difficult task of all updates and so on. I get usually far in the process, then right after a Windows Update (you are prompted to restart) I get the error message «lsass.exe. system error ‘. The PC will not boot in any mode to the current and therefore the recovery of the PC again.

    The restoration of the first PC was due to a problem of System32 hal.dll.

    I don’t know if my original problem of system32 or Windows Update is triggering my problem of Lsass.exe.

    After reading these forums, it seems to be a problem for many people and there are no answers. A lot of people (like me) thought it was a (i) sass and not a sass (l) so there is even a ton of problems listed under isass.exe.

    It seems that any update of Windows after the SP3, triggers this problem. So I delayed install this update, but how long can I keep that upward?

    Any ideas how can I fix?

    Hello

    Method 1.

    Try the steps listed in the article below and check.

    Error message that you receive when you restart a Windows XP-based computer: «unable to locate component lsass.exe.
    http://support.Microsoft.com/kb/922371

    Method 2.

    If the problem persists then install the updates one by one and check what particular update is at the origin of the conflict.

    I hope this helps.

    Thank you, and in what concerns:
    Shekhar S — Microsoft technical support.

    Visit our Microsoft answers feedback Forum and let us know what you think.
    If this post can help solve your problem, please click the ‘Mark as answer’ or ‘Useful’ at the top of this message. Marking a post as answer, or relatively useful, you help others find the answer more quickly.

  • event ID 1000 and event ID 1001 related to casetup32.exe and ImmunetProtectDriver

    Hello world

    I have a question. I run this PC on Windows XP SP3. a few minutes earlier, when installing Immunet 3.0, they kept appearing, several error messages associated with casetup.exe. I checked under Component Services and.

    Failing application casetup32.exe, version 3.0.0.18, failed module ntdll.dll, version 5.1.2600.6055, address 0x00010cce failure.

    Event ID: 1000

    of [note], the above error message 8 x.

    Fault-1991979944 bucket.

    Event ID: 1001

    [note], the error message above appeared x 7.

    After the first installation of Immunet 3.0, I restarted my PC. a message appeared that went something like the following, «an important engine of Immnunet could not load…». «I rebooted my PC once again, the error message still appears. After the third, the error message appears. I don’t know yet at latest.

    The next (s) starting or starting system could not load:

    ImmunetProtectDriver

    ImmunetSelfProtectDriver

    Event ID: 7026

    do I need to uninstall and reinstall the program? or something else?

    Here you go:

    http://social.technet.Microsoft.com/wiki/contents/articles/Windows-Server-2008-event-ID-7026-basic-service-control-manager-operations.aspx

    Contact: http://www.immunet.com/contact/index.html

  • PAGE_FAULT_IN_NONPAGED_AREA (50) — Windows Server 2008

    Hi Microsoft supports the team.

    We have Windows server 2008 sp2 enterprise edition-32 bit, once a week, we started receive «PAGE_FAULT_IN_NONPAGED_AREA» error message on this subject. What error come server stops responding and blue screen came up with the error message above, after that, you need to restart the server to begin to work in!

    Please find below the log from the dump file:
    —————————————————————————————————————————————————

    Loading dump file [C:WindowsMinidumpMini080312-01.dmp]
    The mini kernel dump file: only registers and the trace of the stack are available

    Symbol search path is: D:241 RNDSymbolsExtracted
    Executable search path is:
    Could not load the ntoskrnl.exe, 0n2 error Win32 image
    WARNING: Unable to verify timestamp for ntoskrnl.exe
    ERROR: Module load completed but symbols can be loaded for ntoskrnl.exe
    Windows Server 2008/Windows Vista Kernel Version 6002 (Service Pack2) MP (8 procs) free x 86 compatible
    Product: LanManNt, suite: TerminalServer company
    Computer name:
    Kernel base = 0x82a18000 PsLoadedModuleList = 0x82b2fc70
    The debugging session: 23:11:57.714 on Thursday, August 2, 2012 (UTC + 01:00)
    System Uptime: 9 days 15:17:21.963
    Could not load the ntoskrnl.exe, 0n2 error Win32 image
    WARNING: Unable to verify timestamp for ntoskrnl.exe
    ERROR: Module load completed but symbols can be loaded for ntoskrnl.exe
    Loading the kernel symbols
    ………………………………………………………
    ……………………………………………………….
    …………
    Loading user symbols
    Loading unloaded module list
    ……….
    *******************************************************************************
    *                                                                             *
    * Bugcheck analysis *.
    *                                                                             *
    *******************************************************************************

    Use! analyze — v to obtain detailed debugging information.

    Bugcheck 10000050, {f2a45048, 0, b 82, 94299, 0}

    The kernel symbols are FALSE. Correct symbols to do the analysis.

    *************************************************************************
    *************************************************************************
    ***                                                                   ***
    ***                                                                   ***
    Either you have specified an absolute symbol, or your debugger *.
    has no information complete symbol.  Absolute symbol *.
    resolution is disabled by default. Please specify a *.
    complete symbol module! NomSymbole, or activate the resolution *.
    symbols unskilled by typing ‘.symopt 100 ‘. Note that *.
    allowing unqualified symbol with the network symbol resolution *.
    shares of server in the symbol path can cause the debugger to *.
    appear to hang for long periods of time when an incorrect *.
    symbol name is typed or the symbol of the network server is down.     ***
    ***                                                                   ***
    For some commands work properly, your symbol path *.
    should point to .pdb files have the type information complete.      ***
    ***                                                                   ***
    Some (such as the public OS symbols) .pdb files are not *.
    contain the required information.  The contact group that *.
    you provided with these symbols, if you need this command for *.
    work.                                                          ***
    ***                                                                   ***
    Type referenced: nt! _KPRCB *.
    ***                                                                   ***
    *************************************************************************
    *************************************************************************

    ADDITIONAL_DEBUG_TEXT:
    You can run ‘.symfix; .reload’ to try to fix the symbols path and of loading symbol.

    MODULE_NAME: nt

    FAULTING_MODULE: 82a 18000 nt

    DEBUG_FLR_IMAGE_TIMESTAMP: 4f79a9be

    READ_ADDRESS: could not get nt! MmSpecialPoolStart
    Unable to get nt! MmSpecialPoolEnd
    Unable to get nt! MmPagedPoolEnd
    Unable to get nt! MmNonPagedPoolStart
    Unable to get nt! MmSizeOfNonPagedPoolInBytes
    f2a45048

    FAULTING_IP:
    NT + c 17 299
    82b 94299 394724 cmp dword ptr [edi + 24 h], eax

    MM_INTERNAL_CODE: 0

    CUSTOMER_CRASH_COUNT: 1

    DEFAULT_BUCKET_ID: VISTA_DRIVER_FAULT_SERVER

    BUGCHECK_STR: 0 X 50

    CURRENT_IRQL: 0

    LAST_CONTROL_TRANSFER: from 82b9a7f4 to b 82, 94299

    STACK_TEXT:
    WARNING: Information not available stack unwind. Sequence of images may be wrong.
    90e72a8c 82b9a7f4 01000001 4020 009c3f70 nt 009c + 0x17c299
    90e72abc 82b9ae22 c422da20 00000006 01000001 nt + 0x1827f4
    82b 95848 01000001 90e72c60 8000e8d0 nt 90e72b04 + 0x182e22
    90e72b60 82b97fb7 90e72bb4 00000000 00000005 nt + 0x17d848
    90e72bd8 82b9a257 90e72c60 90e72c4c 00000000 nt + 0x17ffb7
    90e72c18 82b9049f 90e72c60 90e72c7b 00000000 nt + 0 x 182257
    90e72d14 82b906d4 82b105a0 00000002 00000002 nt + 0x17849f
    90e72d38 82c6fb01 82b1a13c 8784e020 82abdda2 nt + 0x1786d4
    90e72d7c 82bedfe2 9b1e85b2 00000000 00000000 nt + 0x257b01
    90e72dc0 82a56f0e 82abdca5 00000000 00000001 nt + 0x1d5fe2
    00000000 00000000 00000000 00000000 00000000 nt + 0x3ef0e

    STACK_COMMAND: kb

    FOLLOWUP_IP:
    NT + c 17 299
    82b 94299 394724 cmp dword ptr [edi + 24 h], eax

    SYMBOL_STACK_INDEX: 0

    SYMBOL_NAME: nt + 17 c 299

    FOLLOWUP_NAME: MachineOwner

    Nom_image: ntoskrnl.exe

    BUCKET_ID: WRONG_SYMBOLS

    Follow-up: MachineOwner
    ———

    ———————————————————————————————————————

    Can you please review and guide us more as soon as POSSIBLE.

    Let me know if any other information required for the same thing.

    Kind regards

    Helen Shah

    Hello

    The question you posted would be better suited to the TechNet community. Please visit the link below to find a community that will provide the support you want.

    http://TechNet.Microsoft.com/en-us/WindowsServer/bb310558.aspx

    Hope this information is useful.

  • Windows 8.1 Windows 8.1 Enterprise Windows 8.1 Pro Windows Server 2012 R2 Datacenter Windows Server 2012 R2 Essentials Windows Server 2012 R2 Foundation Windows Server 2012 R2 Standard Еще…Меньше

    Не уверены, если это нужное исправление? Этой проблемы мы добавили в наш Диагностический дамп памяти которой можно подтвердить.

    Симптомы

    Рассмотрим следующий сценарий:

    • Контроллер домена с Windows Server 2012 R2.

    • Расширенный аудит настраивается для «аудит успехов» для «изменения службы каталогов».

    • Включен аудит определенных объектов в AD (пользователь, группа, Подразделение).

    • Объект «аудит включен» успешно переименован.

    В этом случае контроллер домена завершает работу в локальной безопасности центра подсистемы службы (LSASS) и неожиданно перезагружается.

    Решение

    Чтобы устранить эту проблему, установите накопительный пакет обновления 2928680 или установить исправление, описанное в данной статье.

    Сведения об обновлении

    Дополнительные сведения о получении накопительного пакета обновления 2928680 щелкните следующий номер статьи базы знаний Майкрософт:

    2928680 Windows RT 8.1, Windows 8.1 и Windows Server 2012 R2 накопительный пакет обновления: март 2014

    Сведения об исправлении

    Исправление от корпорации Майкрософт доступно. Тем не менее оно предназначено только для устранения проблемы, указанной в данной статье. Предлагаемое исправление должно применяться исключительно в системах, в которых обнаружена эта специфическая неполадка.

    Чтобы устранить эту проблему, обратитесь в службу поддержки пользователей Майкрософт для получения исправления. Полный список телефонов службы поддержки клиентов корпорации Майкрософт и сведения о стоимости поддержки посетите следующий веб-сайт корпорации Майкрософт:

    http://support.microsoft.com/contactus/?ws=supportПримечание. В особых случаях оплата, предусмотренная за обращение в службу поддержки может быть отменена, если специалист службы технической поддержки Майкрософт определит, что обновление будет решением проблемы. Затраты на обычные услуги службы поддержки будут применяться к дополнительным вопросам и проблемам, которые не охватываются конкретным обновлением.

    Предварительные условия

    Для установки этого исправления необходимо наличие Windows 8.1 или Windows Server 2012 R2.

    Сведения о реестре

    Для установки этого исправления нет необходимости вносить изменения в реестр.

    Необходимость перезагрузки

    Не требуется перезагружать компьютер после установки данного исправления.

    Сведения о замене исправлений

    Это исправление не заменяет ранее выпущенные исправления.

    Глобальная версия этого исправления устанавливает файлы с атрибутами, указанными в приведенных ниже таблицах. Дата и время для файлов указаны в формате UTC. Дата и время для файлов на локальном компьютере отображаются в местном времени с вашим текущим смещением летнего времени (DST). Кроме того, при выполнении определенных операций с файлами, даты и время могут изменяться.

    Примечания к сведениям о файле Windows 8.1 или Windows Server 2012 R2Важно. Windows Server 2012 R2 исправления и исправления Windows 8.1 включаются в тех же самых пакетов. Всегда смотрите раздел «Информация в данной статье относится к следующим продуктам» статьи для определения фактических операционных систем, к которым применяется каждое исправление.

    • Файлы, относящиеся к определенному продукту, этапу разработки (RTM, SPn) и направлению поддержки (LDR, GDR) можно определить по номерам версий, как показано в следующей таблице.

      Версия

      Продукт

      Контрольная точка

      Направление поддержки

      6.3.960 0.16xxx

      Windows 8.1 и Windows Server 2012 R2

      RTM

      GDR

    • Файлы МАНИФЕСТА (.manifest) и MUM (.mum), устанавливаемые для каждой среды, указаны отдельно в разделе Дополнительные сведения о файлах» для Windows 8.1 и Windows Server 2012 R2». MUM, MANIFEST и связанные файлы каталога безопасности (.cat) очень важны для поддержания состояния обновленных компонентов. Файлы каталога безопасности, для которых не перечислены атрибуты, подписаны цифровой подписью корпорации Майкрософт.

    Для всех поддерживаемых 32-разрядных версий Windows 8.1

    Имя файла

    Версия файла

    Размер файла

    Дата

    Время

    Платформа

    Ntdsai.dll

    6.3.9600.16517

    2,556,928

    17-Jan-2014

    16:46

    x86

    Для всех поддерживаемых 64-разрядных версий Windows 8.1 и Windows Server 2012 R2

    Имя файла

    Версия файла

    Размер файла

    Дата

    Время

    Платформа

    Ntdsai.dll

    6.3.9600.16517

    3,652,608

    17-Jan-2014

    17:00

    x64

    Статус

    Корпорация Майкрософт подтверждает, что это проблема продуктов Майкрософт, перечисленных в разделе «Относится к».

    Дополнительные сведения

    Для получения дополнительных сведений о терминологии обновлений программного обеспечения щелкните следующий номер статьи базы знаний Майкрософт:

    Описание 824684 Стандартные термины, используемые при описании обновлений программных продуктов МайкрософтДля запуска операции переименования объекта известны следующие средства:

    • Active Directory — пользователи и компьютеры (ADUC или DSA. MSC)

    • Центр администрирования Active Directory (ADAC или DSAC. (EXE)

    • Active Directory — сайты и службы (DSSITE. MSC)

    • ADSIEDIT.MSC

    • Диспетчер DNS (DNSMGMT. MSC) при изменении области зоны и, возможно, другие такие операции, как удаление DNS зон

    • Консоль управления Exchange 2007

    • LDP.EXE

    • Переименование AdoObject PowerShell командлетов для

    Пример записи журнала событий выводятся следующие сведения журнала событий:

    Приложения ошибки события с кодом 1000
    Имя журнала: приложения
    Источник события: Ошибка приложения
    Событие с кодом 1000
    Виновный имя приложения: lsass.exe, версия: 6.3.9600.16384, штамп времени: 0x5215e25f
    Виновный имя модуля: ntdsai.dll, версия: 6.3.9600.16421, штамп времени: 0x524fcaed
    Код исключения: 0xc0000005
    Смещение: 0x000000000019e45d
    Этот идентификатор процесса: 0x214
    Сбойное приложение время начала: 0x01cefa6743edbeec
    Этот путь приложения: C:Windowssystem32lsass.exe
    Путь к модулю виновный: C:Windowssystem32ntdsai.dll
    Номер отчета: d4cd7581-665c-11e3-80d7-005056984a2b
    Виновный полное имя пакета:
    Этот код приложения относительно пакета:

    Событий Microsoft Windows Wininit 1015
    Имя журнала: приложения
    Источник: Microsoft-Windows-Wininit
    Дата: 22.01.2014 13:43:47
    Код события: 1015
    Описание: Критический системный процесс, C:WINDOWSsystem32lsass.exe, произошел сбой c0000005 код состояния. Необходимо перезагрузить компьютер.

    Сведения о дополнительных файлах для Windows Server 2012 R2 и Windows 8.1

    Дополнительные файлы для всех поддерживаемых 32-разрядных версий Windows 8.1

    Свойства файла

    Значение

    Имя файла

    X86_99153ad436a1df0f36665dd886da0c0a_31bf3856ad364e35_6.3.9600.16517_none_9411b57a5f5b2d15.manifest

    Версия файла

    Неприменимо

    Размер файла

    712

    Дата (UTC)

    18-Jan-2014

    Время (UTC)

    06:23

    Платформа

    Неприменимо

    Имя файла

    X86_microsoft-windows-d..toryservices-ntdsai_31bf3856ad364e35_6.3.9600.16517_none_85b4ba91d480dc99.manifest

    Версия файла

    Неприменимо

    Размер файла

    3,352

    Дата (UTC)

    17-Jan-2014

    Время (UTC)

    22:27

    Платформа

    Неприменимо

    Дополнительные файлы для всех поддерживаемых версий на базе x64 Windows 8.1 и Windows Server 2012 R2

    Свойства файла

    Значение

    Имя файла

    Amd64_834f935bdff3212878df07ff93d59a7f_31bf3856ad364e35_6.3.9600.16517_none_8cd7c1227151bd5b.manifest

    Версия файла

    Неприменимо

    Размер файла

    716

    Дата (UTC)

    18-Jan-2014

    Время (UTC)

    06:22

    Платформа

    Неприменимо

    Имя файла

    Amd64_microsoft-windows-d..toryservices-ntdsai_31bf3856ad364e35_6.3.9600.16517_none_e1d356158cde4dcf.manifest

    Версия файла

    Неприменимо

    Размер файла

    3,356

    Дата (UTC)

    18-Jan-2014

    Время (UTC)

    00:30

    Платформа

    Неприменимо

    Нужна дополнительная помощь?

    Нужны дополнительные параметры?

    Изучите преимущества подписки, просмотрите учебные курсы, узнайте, как защитить свое устройство и т. д.

    В сообществах можно задавать вопросы и отвечать на них, отправлять отзывы и консультироваться с экспертами разных профилей.

    • Remove From My Forums
    • Question

    • System:Window 2012

      Error Message:

      A critical system process, C:Windowssystem32lsass.exe, failed with status code c00000fd.  The machine must now be restarted.

      I started myself window service, The log have other log:

      System.AccessViolationException: Attempted to read or write protected memory. This is often an indication that other memory is corrupt.

      And wait 3-4min, The server will restart.

      • Edited by

        Wednesday, April 27, 2016 9:02 AM

    Answers

    • Hi,

      Thanks for your reply.

      The «-1073741571» error may occur if the registry data type for the SearchList entry is set to a Dword value type (REG_DWORD) instead of to a String value type (REG_SZ) in the registry.

      To resolve the problem that is related to the «-1073741571» error, follow these steps:

      1. Start your computer in Safe Mode.

      2. Click Start, click Run, type regedit in the
      Open box, and then click OK.

      3. Locate and expand the following registry subkey:

      HKEY_LOCAL_MACHINESYSTEMCurrentControlSetServicesTcpipParameters

      4. Change the data type from REG_DWORD to REG_SZ. To do this, follow these steps:

      1. In the right pane, right-click SearchList, and then click
        Delete
        .
      2. Click Yes to confirm that you want to delete this entry.
      3. On the Edit menu, point to New, and then click
        String Value.     
      4. Type SearchList, and then click OK.

      5. Quit Registry Editor.

      6. Restart your computer.

      Note: Taking a backup before modifying the registry.

      Best Regards,

      Alvin Wang


      Please remember to mark the replies as answers if they help and un-mark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact tnmff@microsoft.com.

      • Edited by
        Alvwan
        Tuesday, May 3, 2016 9:34 AM
      • Proposed as answer by
        Alvwan
        Monday, May 9, 2016 8:00 AM
      • Marked as answer by
        Alvwan
        Thursday, May 12, 2016 8:33 AM

    Hello,

    I have been battling some blue screens and dism and sfc can find errors it cannot repair

    I have noticed an error in the log that doesn’t provide much information. I have seen similar posts about specific updates that needed to be kind of overwritten with a dism patch and a specific update download but I don’t know how to figure out what update it would need to be to try to do so.

    Text

    0 of 1 instances of system store corruption have been repaired. Unrepaired corruptions may lead to failures in future system servicing.
    

    Text

    - <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
    - <System>
      <Provider Name="Microsoft-Windows-Servicing" Guid="{BD12F3B8-FC40-4A61-A307-B7A013A069C1}" /> 
      <EventID>1015</EventID> 
      <Version>0</Version> 
      <Level>3</Level> 
      <Task>0</Task> 
      <Opcode>0</Opcode> 
      <Keywords>0x8000000000000000</Keywords> 
      <TimeCreated SystemTime="2022-09-30T00:44:08.277433400Z" /> 
      <EventRecordID>259</EventRecordID> 
      <Correlation /> 
      <Execution ProcessID="9632" ThreadID="6196" /> 
      <Channel>Setup</Channel> 
      <Computer>Server.ConAcc.local</Computer> 
      <Security UserID="S-1-5-18" /> 
      </System>
    - <UserData>
    - <CbsStoreCorruptionRepairFinish xmlns="http://manifests.microsoft.com/win/2004/08/windows/setup_provider">
      <Repaired>0x0</Repaired> 
      <TotalCorruption>0</TotalCorruption> 
      </CbsStoreCorruptionRepairFinish>
      </UserData>
      </Event>
    

    Does anyone have any ideas about how i can figure this out?

    The server was freshly reformatted a couple of weeks back for another reason.

    If it helps I can say that windows update hasn’t located a whole lot of patches to install. I tried to use the troubleshooter to repair windows update, which it said it fixed an error, but it still is unable to find any.

    Image: post contentDo you think maybe I should try to uninstall some and try to reinstall them?

    Возможно, вам также будет интересно:

  • 10054 ошибка соединения с сервером
  • 10053 ошибка соединения с сервером
  • 10051 ошибка network is unreachable
  • 10049 ошибка соединения с сервером
  • 1004 ошибка опель астра h расшифровка

  • Понравилась статья? Поделить с друзьями:
    0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии